Why choose WTZN7100 for Water quality online turbidity analyzer Monitor Turbidity
·High detection sensitivity: Tungsten light source is used,Visible light detection using scattering is about 9 times more sensitive than infrared light,Higher detection sensitivity;
·Built-in defoaming device: Continuous flow bubble elimination is built into the instrument,Used to remove air bubbles from water samples, And make the water flow in the detection area stable,Thus, the interference caused by bubbles and velocity changes is eliminated;
·Simple calibration operation:Available with formhydrazine calibration solution,Visual calibration can be performed with formhydrazine calibration solution,Calibration with 0NTU and 20NTU (recommended),Calibration can also be customized from 0 to 40NTU;
·90°Light scattering method: By design to receive scattered light in 90° direction,Most of the interference of stray light and secondary scattered light is eliminated, The scattering light in 90° direction is not sensitive to particle shape change and has good linearity in low turbidity detection;
·Customize the detection interval:The user can set the detection cycle interval measurement to extend the instrument life;
·Creep pump sampling:Water pressure injection or optional peristaltic pump sampling;
Matching ALPHAPEC 700 display and control terminal.
Technical Data
item | index |
90 degree light scattering method | |
Detection range | 0.0000~99.9999NTU |
Detection accuracy | 0~40NTU:±2% or ±0.02 of the showing data, choose greater one 40~100NTU:showing data±5% |
repeatability | Superior to the showing data ±1% |
Resolution | 0.0001NTU |
Signal averaging | inequality,6s,30s,60s,90s can be choosed |
24VDC | |
Operating temperature | 0℃~45℃ |
Sample temperature | 0℃~40℃ |
Sample velocity | 200~750ml/min |
Class of protection | |
Calibration method | Self-supplied liquid calibration, standard calibration, manual calibration |
Digital communication | RS485,Standard MODBUS protocol |
Inlet port | NPT1/4 Internal thread |
Outlet port | NPT1/2 Internal thread |
Communication cable | Acquiesce 2m(customsized ) |
Size | 230*226*450mm |
Installation mode | wall-mounted |
Sample pump | Peristaltic pump (optional) |
Application Field
Turbidity monitoring of water before, after, precipitation and leaving the factory;
·Industrial process of circulating cooling water, activated carbon filter effluent water quality monitoring;
·Municipal pipe network water quality monitoring;
·Regional secondary feed water quality monitoring.
Company Information
Weite Technologies Co.,Ltd
FAQ
Q. How long is the warranty?
A. We offer 1-years-warranty
Q. What's the MOQ?
A. 1pc. We welcome clients to order samples to test quality.
Q. How long is the delivery time?
A. Sample order 3-5 working days, bulk order 7-15 working days.
Q. Why do you choose us?
A. We are the leading manufacturer in this industry.
Work with us, you will always get top quality with fair price, newest products.
Q. What is the package?
A. custonized
Add.:No.6 Gangcheng Road,Yichang,Free Trade Zone(Hubei) China 443005
86-15507209968(whatsapp)